[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$f2wGhAP5Kji1LOQU-yvQqx90qi9yV9YKTHfOW_HXB698":3,"g5a-risk:CVE-2025-40812":174},{"success":4,"data":5,"meta":171},true,{"cveId":6,"title":7,"description":8,"shortDescription":9,"publishedDate":10,"lastModified":11,"cvssScore":12,"cvssVector":13,"cvssMetrics":14,"epssScore":32,"epssPercentile":27,"epssTimeSeries":33,"severity":34,"affectedProducts":35,"affectedProductsCount":50,"references":51,"referencesCount":57,"weaknesses":58,"weaknessesCount":57,"isActivelyExploited":67,"cisaInfo":27,"otxData":27,"relatedBlogPosts":68,"seoMetadata":69,"configurations":94,"relatedVendorCves":162,"notableEvents":163},"CVE-2025-40812","What is CVE-2025-40812?","A vulnerability has been identified in Solid Edge SE2024 (All versions \u003C V224.0 Update 14), Solid Edge SE2025 (All versions \u003C V225.0 Update 6). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.","A vulnerability has been identified in Solid Edge SE2024 (All versions \u003C V224.0 Update 14), Solid Edge SE2025 (All versions \u003C V225.0 Update 6). The affected ...","2025-10-14T10:15:40.09","2025-10-16T13:50:53.083",7.8,"CVSS:3.1\u002FAV:L\u002FAC:L\u002FPR:N\u002FUI:R\u002FS:U\u002FC:H\u002FI:H\u002FA:H",{"CVSSMetricV31":15,"CVSSMetricV30":30,"CVSSMetricV2":31,"CVSSMetricV40":27},[16],{"Source":17,"Type":18,"CVSSData":19,"ExploitabilityScore":28,"ImpactScore":29},"productcert@siemens.com","Primary",{"Version":20,"VectorString":13,"AttackVector":21,"AttackComplexity":22,"PrivilegesRequired":23,"UserInteraction":24,"Scope":25,"ConfidentialityImpact":26,"IntegrityImpact":26,"AvailabilityImpact":26,"BaseScore":12,"BaseSeverity":26,"ExploitCodeMaturity":27,"RemediationLevel":27,"ReportConfidence":27,"TemporalScore":27,"TemporalSeverity":27,"ConfidentialityRequirement":27,"IntegrityRequirement":27,"AvailabilityRequirement":27,"ModifiedAttackVector":27,"ModifiedAttackComplexity":27,"ModifiedPrivilegesRequired":27,"ModifiedUserInteraction":27,"ModifiedScope":27,"ModifiedConfidentialityImpact":27,"ModifiedIntegrityImpact":27,"ModifiedAvailabilityImpact":27,"EnvironmentalScore":27,"EnvironmentalSeverity":27},"3.1","LOCAL","LOW","NONE","REQUIRED","UNCHANGED","HIGH",null,1.8,5.9,[],[],0.00126,[32,32,32,32,32,32,32],"High",[36,41,44,47],{"vendor":37,"product":38,"version":39,"criteria":40,"vulnerable":4},"siemens","solid_edge_se2024","-","cpe:2.3:a:siemens:solid_edge_se2024:-:*:*:*:*:*:*:*",{"vendor":37,"product":38,"version":42,"criteria":43,"vulnerable":4},"224.0","cpe:2.3:a:siemens:solid_edge_se2024:224.0:-:*:*:*:*:*:*",{"vendor":37,"product":45,"version":39,"criteria":46,"vulnerable":4},"solid_edge_se2025","cpe:2.3:a:siemens:solid_edge_se2025:-:*:*:*:*:*:*:*",{"vendor":37,"product":45,"version":48,"criteria":49,"vulnerable":4},"225.0","cpe:2.3:a:siemens:solid_edge_se2025:225.0:-:*:*:*:*:*:*",4,[52],{"url":53,"source":54,"tags":55},"https:\u002F\u002Fcert-portal.siemens.com\u002Fproductcert\u002Fhtml\u002Fssa-541582.html","Siemens",[56],"Vendor Advisory",1,[59],{"id":60,"name":61,"description":62,"extendedDescription":63,"status":64,"abstraction":65,"structure":66},"CWE-125","Out-of-bounds Read","The product reads data past the end, or before the beginning, of the intended buffer.","","Draft","Base","Simple",false,[],{"title":70,"metaDescription":71,"keywords":72,"canonicalUrl":73,"structuredData":74},"What is CVE-2025-40812? Vulnerability Analysis | Security Advisory | EdgeProtect","Comprehensive analysis of CVE-2025-40812, a high severity cyber security vulnerability from 2025. A vulnerability has been identified in Solid Edge SE2024 (A...","CVE-2025-40812, CVE-2025-40812 vulnerability, CVE-2025-40812 security, high severity vulnerability, cybersecurity, vulnerability analysis, security advisory, CVE database, threat intelligence, security research, vulnerability assessment, cyber threats, 2025, CVSS score, exploit, patch, remediation, siemens security, solid_edge_se2024 vulnerability, solid_edge_se2025 vulnerability","\u002Fwhat-is\u002Fcve-2025-40812",{"@context":75,"@type":76,"headline":70,"description":71,"datePublished":10,"dateModified":11,"author":77,"publisher":81,"about":85,"mainEntityOfPage":89,"articleSection":92,"keywords":93},"https:\u002F\u002Fschema.org","TechArticle",{"@type":78,"name":79,"url":80},"Organization","EdgeProtect","https:\u002F\u002Fedgeprotect.io",{"@type":78,"name":79,"url":80,"logo":82},{"@type":83,"url":84},"ImageObject","https:\u002F\u002Fedgeprotect.io\u002Fimg\u002Flogos\u002Fedgeprotect-logo-512.png",{"@type":86,"name":6,"description":87,"additionalType":88},"Thing","Cybersecurity Vulnerability","https:\u002F\u002Fschema.org\u002FSoftwareBug",{"@type":90,"@id":91},"WebPage","https:\u002F\u002Fedgeprotect.io\u002Fwhat-is\u002Fcve-2025-40812","Cybersecurity","CVE-2025-40812, CVE-2025-40812 vulnerability, CVE-2025-40812 security, high severity vulnerability, cybersecurity, vulnerability analysis, security advisory, CVE database, threat intelligence, security research",[95],{"Operator":27,"Negate":27,"Nodes":96},[97],{"Operator":98,"Negate":67,"CPEMatch":99},"OR",[100,102,104,107,110,113,116,119,122,125,128,131,134,137,140,143,145,147,150,153,156,159],{"Vulnerable":4,"Criteria":40,"MatchCriteriaID":101,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"893736B3-0140-4775-8700-CB9D7719DDE5",{"Vulnerable":4,"Criteria":43,"MatchCriteriaID":103,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"A0119E8F-1FAF-4A3B-B6E9-20F78360FC82",{"Vulnerable":4,"Criteria":105,"MatchCriteriaID":106,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0001:*:*:*:*:*:*","829C4AEB-7C8D-408B-A79C-8684753F45E1",{"Vulnerable":4,"Criteria":108,"MatchCriteriaID":109,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00010:*:*:*:*:*:*","8E262AB3-8C47-430A-9D42-89317CB630C5",{"Vulnerable":4,"Criteria":111,"MatchCriteriaID":112,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00011:*:*:*:*:*:*","94758C94-F427-480E-A9F1-109D8660C4E0",{"Vulnerable":4,"Criteria":114,"MatchCriteriaID":115,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00012:*:*:*:*:*:*","D084D11C-08FB-4EEE-A5E3-D93C10103D2A",{"Vulnerable":4,"Criteria":117,"MatchCriteriaID":118,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00013:*:*:*:*:*:*","F8A834C5-1E45-4087-A3A4-C059A2C9960C",{"Vulnerable":4,"Criteria":120,"MatchCriteriaID":121,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0002:*:*:*:*:*:*","1E8FB23E-280D-46FD-BD44-5D4552639E00",{"Vulnerable":4,"Criteria":123,"MatchCriteriaID":124,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0003:*:*:*:*:*:*","CA2417A0-DD31-46FC-8D5A-9128B86C9352",{"Vulnerable":4,"Criteria":126,"MatchCriteriaID":127,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0004:*:*:*:*:*:*","3CA9C494-767C-4CFA-AB07-106298B7B2C4",{"Vulnerable":4,"Criteria":129,"MatchCriteriaID":130,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0005:*:*:*:*:*:*","C3738D73-82A5-41E4-8083-34611A6301BE",{"Vulnerable":4,"Criteria":132,"MatchCriteriaID":133,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0006:*:*:*:*:*:*","5634352F-0DD1-4731-9E43-61D0A9A40D1B",{"Vulnerable":4,"Criteria":135,"MatchCriteriaID":136,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0007:*:*:*:*:*:*","32E3D549-54F0-4909-830D-BDE8CDAD5AF7",{"Vulnerable":4,"Criteria":138,"MatchCriteriaID":139,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0008:*:*:*:*:*:*","1137D7B3-17AD-4997-AC19-4308AA5C9438",{"Vulnerable":4,"Criteria":141,"MatchCriteriaID":142,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0009:*:*:*:*:*:*","E5488DEB-3165-4F88-8C63-7B9BC212DEFF",{"Vulnerable":4,"Criteria":46,"MatchCriteriaID":144,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"9EBC379B-A9D5-4587-87A1-59D2D8EF2267",{"Vulnerable":4,"Criteria":49,"MatchCriteriaID":146,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"3D717792-2F86-43CD-973B-249171094C6C",{"Vulnerable":4,"Criteria":148,"MatchCriteriaID":149,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0001:*:*:*:*:*:*","2C6F3C20-8AB5-4A6A-8524-C7CBC4A4D973",{"Vulnerable":4,"Criteria":151,"MatchCriteriaID":152,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0002:*:*:*:*:*:*","03CCA3A8-F8D6-4C80-BC03-15B865CE46B7",{"Vulnerable":4,"Criteria":154,"MatchCriteriaID":155,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0003:*:*:*:*:*:*","B51556E8-9A3B-4755-BC2C-8FACABC01A7B",{"Vulnerable":4,"Criteria":157,"MatchCriteriaID":158,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0004:*:*:*:*:*:*","737A4807-387D-4099-880D-2CCEE7B77B44",{"Vulnerable":4,"Criteria":160,"MatchCriteriaID":161,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0005:*:*:*:*:*:*","9267F09C-5EFD-443F-ABE0-974C1D034464",[],[164],{"id":165,"eventType":166,"eventTime":167,"details":168,"label":169,"color":170},"cc0859cd-e311-416f-89f7-36b3cb37da1e","NEW_NVD","2025-10-15T04:01:16.297059+00:00","New CVE added to NVD","Published to NVD","blue",{"lastModified":11,"cacheTime":172,"version":173},1793215458565,"2.0",{"score":175,"band":176,"action":177,"scoredAt":178},46,"Medium","Plan remediation","2026-07-01T10:37:52.895446+00:00"]