[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fn-KuDHfHA3NTTJata_Nk2fohebPANEeAud-YCwOiSNk":3,"g5a-ex:rockwellautomation\u002F1756-eweb@*":80,"g5a-family:rockwellautomation\u002F1756-eweb":82},{"success":4,"data":5},true,{"product":6,"versions":14,"topVulnerabilitiesByEpss":15,"kevVulnerabilities":58,"seoMetadata":59,"meta":77},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":9,"lastCveUpdate":11,"versions":12,"description":13},"rockwellautomation","1756-eweb",0,8,"2013-01-24",[],"1756-eweb by Rockwellautomation is a technology product and 8 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[],[16,24,31,35,39,42,47,53],{"cveId":17,"description":18,"publishedDate":11,"cvssScore":19,"cvssVersion":20,"severity":21,"isKev":22,"epssScore":23},"CVE-2012-6441","An information exposure of confidential information results when the device receives a specially crafted CIP packet to Port 2222\u002FTCP, Port 2222\u002FUDP, Port 44818\u002FTCP, or Port 44818\u002FUDP. Successful exploitation of this vulnerability could cause loss of confidentiality.\n\n\n\n\n\nRockwell Automation EtherNet\u002FIP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I\u002FO EtherNet\u002FIP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400",5,"v2","Medium",false,0.54168,{"cveId":25,"description":26,"publishedDate":11,"cvssScore":27,"cvssVersion":28,"severity":29,"isKev":22,"epssScore":30},"CVE-2012-6435","When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222\u002FTCP, Port 2222\u002FUDP, Port 44818\u002FTCP, or Port 44818\u002FUDP that instructs the CPU to stop logic execution and enter a fault state, a DoS can occur. This situation could cause loss of availability and a disruption of communication with other connected devices.\n\n\n\n\n\nRockwell Automation EtherNet\u002FIP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I\u002FO EtherNet\u002FIP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400",7.5,"v3.1","High",0.41888,{"cveId":32,"description":33,"publishedDate":11,"cvssScore":27,"cvssVersion":28,"severity":29,"isKev":22,"epssScore":34},"CVE-2012-6442","When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222\u002FTCP, Port 2222\u002FUDP, Port 44818\u002FTCP, or Port 44818\u002FUDP that instructs the product to reset, a DoS can occur. This situation could cause loss of availability and a disruption of communication with other connected devices.\n\n\n\nRockwell Automation EtherNet\u002FIP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I\u002FO EtherNet\u002FIP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400",0.32807,{"cveId":36,"description":37,"publishedDate":11,"cvssScore":27,"cvssVersion":28,"severity":29,"isKev":22,"epssScore":38},"CVE-2012-6438","The device does not properly validate the data being sent to the buffer. An attacker can send a malformed CIP packet to Port 2222\u002FTCP, Port 2222\u002FUDP, Port 44818\u002FTCP, or Port 44818\u002FUDP, which creates a buffer overflow and causes the NIC to crash. Successful exploitation of this vulnerability could cause loss of availability and a disruption in communications with other connected devices.\n\n\n\n\n\nRockwell Automation EtherNet\u002FIP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I\u002FO EtherNet\u002FIP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400",0.32728,{"cveId":40,"description":41,"publishedDate":11,"cvssScore":27,"cvssVersion":28,"severity":29,"isKev":22,"epssScore":38},"CVE-2012-6436","The device does not properly validate the data being sent to the buffer. An attacker can send a malformed CIP packet to Port 2222\u002FTCP, Port 2222\u002FUDP, Port 44818\u002FTCP, or Port 44818\u002FUDP, which creates a buffer overflow and causes the CPU to crash. Successful exploitation of this vulnerability could cause loss of availability and a disruption in communications with other connected devices.\n\n\n\n\n\n\n\nRockwell Automation EtherNet\u002FIP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I\u002FO EtherNet\u002FIP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400",{"cveId":43,"description":44,"publishedDate":11,"cvssScore":45,"cvssVersion":20,"severity":29,"isKev":22,"epssScore":46},"CVE-2012-6439","When an affected \nproduct receives a valid CIP message from an unauthorized or unintended \nsource to Port 2222\u002FTCP, Port 2222\u002FUDP, Port 44818\u002FTCP, or Port \n44818\u002FUDP that changes the product’s configuration and network \nparameters, a DoS condition can occur. This situation could cause loss \nof availability and a disruption of communication with other connected \ndevices. \n\nRockwell Automation EtherNet\u002FIP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I\u002FO EtherNet\u002FIP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400",8.5,0.28348,{"cveId":48,"description":49,"publishedDate":11,"cvssScore":50,"cvssVersion":28,"severity":51,"isKev":22,"epssScore":52},"CVE-2012-6437","The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware image to the Ethernet card, whether it is a corrupt or legitimate firmware image. Successful exploitation of this vulnerability could cause loss of availability, integrity, and confidentiality and a disruption in communications with other connected devices.\n\n\n\n\n\nRockwell Automation EtherNet\u002FIP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I\u002FO EtherNet\u002FIP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400",9.8,"Critical",0.09579,{"cveId":54,"description":55,"publishedDate":11,"cvssScore":56,"cvssVersion":28,"severity":21,"isKev":22,"epssScore":57},"CVE-2012-6440","The Web server password authentication mechanism used by the products is vulnerable to a MitM and Replay attack. Successful exploitation of this vulnerability will allow unauthorized access of the product’s Web server to view and alter product configuration and diagnostics information.\n\n\n\nRockwell Automation EtherNet\u002FIP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I\u002FO EtherNet\u002FIP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400",4.8,0.08121,[],{"title":60,"metaDescription":61,"keywords":62,"structuredData":63},"1756-eweb by Rockwellautomation - Security Vulnerabilities & Analysis | EdgeProtect","Comprehensive security analysis for 1756-eweb by Rockwellautomation with 8 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","1756-eweb vulnerabilities, 1756-eweb security, 1756-eweb CVE, Rockwellautomation 1756-eweb, 1756-eweb threat intelligence, Rockwellautomation security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":64,"@type":65,"name":8,"description":61,"url":66,"manufacturer":67,"applicationCategory":71,"softwareVersion":72,"mainEntity":73},"https:\u002F\u002Fschema.org","SoftwareApplication","https:\u002F\u002Fedgeprotect.io\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Frockwellautomation\u002F1756-eweb",{"@type":68,"name":69,"url":70},"Organization","Rockwellautomation","https:\u002F\u002Fedgeprotect.io\u002Fvendors\u002Frockwellautomation","Security Software","Multiple versions",{"@type":74,"name":75,"description":76,"vulnerabilityCount":10,"dateModified":11},"SecurityVulnerability","1756-eweb Security Vulnerabilities","Security vulnerabilities affecting 1756-eweb by Rockwellautomation",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":9,"lastUpdated":11,"generatedAt":78,"apiVersion":79},"2026-10-28T16:44:11.445Z","3.0",{"rows":81,"total":9,"capped":22,"failed":9},[],[83,86,88,90],{"product":84,"cves":85},"1756-eweb_series_a",1,{"product":87,"cves":85},"1756-eweb_series_a_firmware",{"product":89,"cves":85},"1756-eweb_series_b",{"product":91,"cves":85},"1756-eweb_series_b_firmware"]